3.2.5 Mode Description

3.2.5.1 Counter Mode, 0

Using the cascaded configuration (32 bit counter), the Most Significant Counter (MSC) must operate in the counter mode. With this mode, the MSC reacts only on the up and/or down pulse from the Least Significant Counter (LSC). The MSC device is hardwired to this mode.

Note: The LSC should not be asserted in the counter mode, since this will not result in any reaction when Quadrature signal levels are changed.

CC133 - 12 Channel Incremental Encoder Interface With Isolated Inputs - 30 SEP 1996
Copyright © 1996 Compcontrol, Inc.