[Previous] [Up] [Top] [Contents] [Back]4.4 Jumper Settings
When the connection is made between pins 1 and 2 of JB1, the module will respond to both Supervisory AM code $2D and non privileged AM code $29. When pins 2 and 3 are connected, the module will respond only to the Supervisory AM code $2D.
Figure 4-1 Jumper JB1 - Access Mode