[Previous] [Up] [Top] [Contents] [Back]Chapter 4 Installation Procedure
All jumper settings discussed in the following sections are illustrated as seen from the component side with the VMEbus connectors downwards. The next table gives a summary of the default jumper and switch settings and their function.
| Description | Jumper Block | Default Setting | Status | Section | 
|---|---|---|---|---|
| Network Time Out | JB1 | Not Connected | Max. 4 miles | 4.3.1 | 
| Cable Ground | JB2 | 1-2 Connected | VMEbus GND | 4.3.2 | 
| IRQ Level | JB3 | 5-6 Connected | Level 3 | 4.3.3 | 
| Access Mode | JB4 | Not Connected | Both sup. and n.p. | 4.3.4 | 
| Addressing Mode | JB5 | 2-3 Connected | Short addressing | 4.3.4 | 
| Coax Termination | JB6 | Not Connected | High Impedance | 4.3.5 | 
| Node ID | SW1 | Switch 5 ON, rest OFF | Node ID $10 | 4.3.6 | 
| Address (A15-A12) | SW2 | 'D' | Address $D000 | 4.3.4 | 
| Address (A19-A16) | SW3 | 'F' | Don't care | 4.3.4 | 
| Address (A23-A20) | SW4 | 'F' | Don't Care | 4.3.4 | 